Volume 21, Issue 3 (Dental Supplement 2013)                   JSSU 2013, 21(3): 395-406 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Daneshkazemi A, Davari A, mousavinasab M, Hatamihajiagha M, haddad M. Effect of Loadcycling Number on Microleakage of Class V Preparation Restored with Composite and Total Etch Adhesives. JSSU 2013; 21 (3) :395-406
URL: http://jssu.ssu.ac.ir/article-1-2384-en.html
Abstract:   (23896 Views)
Introduction: Characteristics of Dental materials may be examined under stimulated oral conditions like loadcycling and Thermocycling. The aim of this study was to evaluate the effect of loadcycling on microleakage of class V cavity preparations restored with composite and total etch adhesives. Methods: One hundred class V preparations (5mm×3 mm and 2.5mm axial Depth) with incisal margin in enamel and gingival margin in dentin, were prepared in the anterior bovine teeth. The teeth were randomly divided into two groups which restored with single Bond (3M-USA) or excite (Ivaclar/viva dent/Lichtenstein). Each group was further divided into five subgroups. The numbers of used loadcycles involved respectively 0, 50k, 100k, 200k, 300k. [K=1000] Then, all the teeth were covered with sticky wax except 1mm around the samples and were immersed in 2% methylene blue for 24 hours. Then all the teeth were sectioned longitudinally and the scores of Dye penetration were registered under stereomicroscope. The study data were analyzed using kruskal Wallis and Mann Whitney and wilcoxon tests. Results: All the dentin margins showed higher microleakage than enamel margin (P=0.0001). There was no significant difference between the microleakage of single bond and Excite(P>0/05). The effect of the number of loadcycles on the microleakage of the single bond and Excite in dentin and enamel margin was not significant. Conclusion: Enamel margins showed less microleakage than dentin margins. This study did not show any increase in microleakage after increasing the number of loadcycles
Full-Text [PDF 472 kb]   (1982 Downloads)    
Type of Study: Original article | Subject: Dental
Received: 2013/05/11 | Accepted: 2013/09/28 | Published: 2013/09/28

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | SSU_Journals

Designed & Developed by : Yektaweb