<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>The Journal of Shahid Sadoughi University of Medical Sciences</title>
<title_fa>مجله علمي پژوهشي دانشگاه علوم پزشكي شهید صدوقی يزد</title_fa>
<short_title>JSSU</short_title>
<subject>Medical Sciences</subject>
<web_url>http://jssu.ssu.ac.ir</web_url>
<journal_hbi_system_id>20</journal_hbi_system_id>
<journal_hbi_system_user>journal20</journal_hbi_system_user>
<journal_id_issn>2228-5741</journal_id_issn>
<journal_id_issn_online>2228-5733</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi></journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>5</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2013</year>
	<month>8</month>
	<day>1</day>
</pubdate>
<volume>21</volume>
<number>3</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه کلینیکی دقت اپکس یاب الکترونیکی و رادیوگرافی در تعیین طول کانال ریشه در دندان‌های مولر شیری</title_fa>
	<title>A Clinical Comparison of Accuracy of an Electronic Apex Locator (EAL) and Radiography in the Determination of Working Length in Primary Molars</title>
	<subject_fa>دندانپزشکی</subject_fa>
	<subject>Dental</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Original article</content_type>
	<abstract_fa>مقدمه: برای موفق بودن درمان پالپکتومی در دندان‌های شیری اندازه‌گیری دقیق طول کانال ریشه لازم است. تعیین طول با استفاده از پرتونگاری رایج‌ترین روش مورد استفاده بوده است، اما به دلیل عوارض ﺳﻮء پرتو و همچنین لزوم همکاری کودک معمولاً با مشکلاتی همراه است. هدف از مطالعه، مقایسه دقت دستگاه آپکس یاب الکترونیکی NSK با پرتو نگاری معمولی برای تعیین طول کانال ریشه مولرهای شیری نکروز بود.
روش بررسی: تعداد 20 عدد دندان مولر شیری 3 کاناله فک پایین (10 دندان D و10 دندان E) در کودکان با رده سنی 7-5 سال با شرط عدم وجود کلسیفیکاسیون در پالپ چمبر و کانال‌ها، عدم درمان ریشه قبلی و پرفوراسیون کف اتاقک پالپی توسط پوسیدگی انتخاب شدند. حفره دسترسی ایجاد شد و طول کانال به وسیله آپکس یاب الکترونیکی NSK و رادیوگرافی تعیین و مقایسه شدند. پالپکتومی کامل شد و داده‌ها با استفاده از آزمون Paired Samples T test تجزیه و تحلیل شدند.
نتایج: در 56 کانال (3/99% موارد) طول اندازه‌گیری شده با آپکس یاب الکترونیکی با طول اندازه‌گیری شده در رادیوگرافی برابر بود. در 3 کانال (5% موارد) طول اندازه‌گیری شده با آپکس یاب 1 میلی‌متر کمتر از طول رادیوگرافی بود و در 1 کانال (7/1% موارد) طول اندازه‌گیری شده با آپکس یاب 1 میلی‌متر بیشتر از طول رادیوگرافی بود. تفاوت معنی‌داری بین این دو شیوه 
اندازه‌گیری دیده نشد (85/0.=p).
نتیجه‌گیری: آپکس یاب NSK در تعیین طول کانال دندان‌های مولر شیری با دقت عمل می‌کند.
</abstract_fa>
	<abstract>Introduction: Radiography is the most common method for measurement of working length, though it is not the ideal method because of technical problems, radiation hazard, superimposition of permanent teeth bud on primary teeth, and so on. Electronic Apex Locator (EAL) is a device for determination of working length. Therefore, this study aimed to compare the accuracy of an electronic apex locator and radiography for determining working length of primary necrotic molars.
Methods: sixty canals of twenty necrotic mandibular primary molars were used in children with 5-7 years old. There were no calcified canal, previous root canal therapy and perforation of pulp chamber floor. Access cavity was prepared and working length was determined by means of NSK EAL and conventional radiography and then was compared. Moreover, Pulpectomy was completed. Data were analyzed by Paired Samples T test. 
Results: In 56(93.3%) of the canals, the length measured by NSK EAL was determined to be equal to the length measured by radiography. In 3 canals(5%),  NSK measurements were found to be less than radiography measurements for 1mm and in 1 canal (1.7%), it was greater than radiography measurements for 1mm. T test analysis indicated no significant difference between the two measurement methods (p=0.85).
Conclusions: Electronic apex locator can accurately assess the length of canals in primary molars.
 
</abstract>
	<keyword_fa>آپکس یاب الکترونیکی، رادیوگرافی، کانال ریشه، پالپکتومی، دندان مولر شیری</keyword_fa>
	<keyword>Electronic Apex Locator; Primary Molar Tooth; Pulpectomy; Radiography; Working Length  </keyword>
	<start_page>360</start_page>
	<end_page>369</end_page>
	<web_url>http://jssu.ssu.ac.ir/browse.php?a_code=A-10-1216-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>S</first_name>
	<middle_name></middle_name>
	<last_name>Rekabi</last_name>
	<suffix></suffix>
	<first_name_fa>صفا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رکابی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>E</first_name>
	<middle_name></middle_name>
	<last_name>Rajaie Behbahani </last_name>
	<suffix></suffix>
	<first_name_fa>الهام</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>رجایی بهبهانی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Soruri</last_name>
	<suffix></suffix>
	<first_name_fa>میلاد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>سروری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


	<author>
	<first_name>Z</first_name>
	<middle_name></middle_name>
	<last_name>Bahrolooloomi</last_name>
	<suffix></suffix>
	<first_name_fa>زهرا</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>بحرالعلومی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation></affiliation>
	<affiliation_fa></affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
